DID YOU KNOW?
The success rate of a gas detection system to detect gas releases in known incidences is only about 60%*.
The effectiveness of the safety shutdown system to mitigate risks arising out of accidental gas releases is highly dependent on the associated gas detection system's ability to reliably detect gas releases, and to detect it quickly. Modern gas detection technologies are now available to help you improve the success rate of gas detection.
Speak to our specialists to understand how MSA's latest gas detection technologies can help you reduce the risks that you face each day.
*Source: HSE UK Statistics - Offshore Hydrocarbon Releases Statistics 2000 (HSE Report # OTO 2000 112).Choose Your Best Defense, Apply Layers of Detection with MSA
No single detection technology can mitigate completely the risks arising out of accidental gas releases.
(1) Ultrasonic Gas Leak Detector | (2) Open Path Gas Detector | (3) New Generation Point Detector | (4) Flame Detector | (5) Portable Gas Detectors
Having multiple layers of detection, is presently the best defense against these risks.
MSA has a very complete range of gas detection technologies, each well suited for detecting a different stage of gas release. This is complemented by a good range of flame detectors, gas and flame mapping tools, safety rated controllers and in-house integration capabilities. We have a very complete solution to protect customers from the risks caused by accidental gas releases.
Learn more on MSA Gas Detection: Layered Gas & Flame Monitoring »
Speak to an MSA Specialist Today
MSA's latest gas detection technologies can help you reduce the risks that you face each day. Learn more from our specialist and request for a consultation today.
Risk Reduction Delivers Better Capital Resources Allocation and Better Protection
Be Better Protected Against…
The gas and flame detection system is put in place to reduce the consequence of gas explosions and fires. Consequences could include one or more of the following:
- Capital loss due to infrastructure damage
- Serious injury or loss of life
- Production loss due to process shutdowns
- Environmental contamination
- Lawsuits
The biggest factor that limits the effectiveness of any gas detection system is Detection Coverage. If the system is unable to detect the gas (i.e. "cover"), then it would not know when to execute the needed safety actions. Detection Coverage is therefore crucial.
Challenge of Risk Reduction
Almost all gas detection technologies need the gas to 'arrive' at the detector (or detection line) in order for detection to occur. In reality, positioning gas detectors to ensure that a high likelihood of this happening is an engineering challenge, especially for outdoor process areas. Mechanical obstructions, area congestion due to equipment and piping, release mechanisms, direction of release, impingement, relative density of the released gas and wind influence, are all factors that influence the behavior of gas plumes and make detector placement a very difficult task for the engineer.
Improving Detection Effectiveness
It is common these days, to find the engineer relying on software tools (i.e. gas dispersion modelling, gas and flame mapping) to help determine detector positions by simulating the behavior of gas releases and the resulting plumes. While there has been significant advances of such tools, a good measure of design assumptions supported by engineering experience is usually still needed. What this means is, a degree of uncertainty often remains. The engineer can attempt to reduce this uncertainty by making more safety conservative assumptions. But a more conservative approach in favor of safety, may also result in a greater number of detectors (i.e. higher CAPEX) and a corresponding increase in maintenance (i.e. higher OPEX). In this era of cost cutting and restraining, this is likely to be a difficult balancing act.
Solutions by MSA
An understanding of different gas detection technologies and its suitability for detecting at different stages of release can make a difference. It is possible to improve detection effectiveness without an excessive increase in detector quantity. This means CAPEX (and OPEX) can be restrained, even when a more safety conservative approach is preferred.
Find out more from MSA Gas Detection Systems Comparison Report on how different detection technologies perform for each consideration of Risk Reduction, CAPEX, and OPEX.
If you wish to speak to our specialists to understand how MSA's latest gas detection technologies can help you reduce the risks that you face each day, request for a consultation today.
Case Study
Open Path Gas Detector
Application Notes
Oil, Gas and Petrochemical
- Compressor Stations
- LNG/CNG Opportunities
- Solutions for the Natural Gas Shale Industry
- Protecting Ethylene Process Facilities from Gas Leaks
- Gas Detection Solutions for Ethylene Applications
- Monitoring Fuel Leaks in Refinery Applications; Engine Test and Fuel Blend Rooms
- Ultima X Chlorine Monitor Calibration
Industrial
- Carbon Dioxide Monitoring in Breweries
- Hydrogen Monitoring in Nuclear Power Plants and Storage Areas
- Hydrogen Detection in Chemical Agent Destruction Processing Applications
- Detection of Volatile Organic Compounds
- Special Application Oxygen Sensors
- Considerations of Oxygen Sensors used for Process Control
- Gas Detection System: 0-100% v/v Methane in Landfill Recovery Gas and Waste Gas Streams
Wastewater
- Fixed Gas & Flame Detection for Four-Gas Wet Well Monitoring
- Gas Monitoring for Wet Well Applications
- Odor Scrubber Monitoring
Custom Gas Sampling/Flow Panels
- Gas Sampling Solutions for Hazardous Environments
- High Performance Filter Media for sever samplingapplications
- H2S Flow Panel System
- Dilution Flow Panels for Combustible Gas Monitoring
- Thermal Conditioning for Extracted Gas Samples
- Air-Cooled Sample Conditioner for High Temperature Gas Sampling
Whitepapers
- Combustible Gas Detection White Paper
A guide to the characteristics of combustible gases and the applicable detection technologies used. - Gas Detection Technologies White Paper
The ability of gas detection technologies to work together is one of the benefits of a new outlook in fixed gas detection systems addressed here. - Hydrogen Gas Detection White Paper
White paper expands on various gas detection technologies used to prevent hydrogen (H2) gas leaks and hazards in the Oil & Gas industry. - IR Gas Detection Technology White Paper
We discuss the infrared sensing technologies for both point and and open-path infrared detection methods. - IR vs Catalytic Bead Technology White Paper
We present when it's better to use Infrared Gas Detectors for combustible gas monitoring rather than Catalytic Bead Gas Detectors. - MC600 Multi-Channel Controller White Paper
Characterizing a multi-channel controller for hydrocarbon, H2S and Toxic gas detection and monitoring. - Neural Network Technology for Flame Detection White Paper
A detailed look into the breakthrough neural network technology used for improving false alarm immunity in flame detection. - Flame Detector Technologies White Paper
Paper examines the various flame detection technologies available today and factors to consider when selecting a flame detector. - SIL 101 - How Safe Do I Need To Be
The global importance of SIL (Safety Integrity Levels) has grown substantially in the oil/gas, petrochemical and other process industries over the last 10 years. - Combustible Gas Detector Sensor Drift: Catalytic vs. Infrared
- Ultima OPIR-5 Open Path Gas Detector: Minimum Separation Distances
- Ultrasound: Protecting the Environment
- Photoacoustic Infrared Technology for Detetion of Refrigerant Gases
- FlameGard 5 MSIR Flame Detector
Multimedia
Fixed Gas and Flame Detection
Fire and Gas Mapping
MSA ALTAIR® 5X Portable Multigas Detector
MSA Ultima MOS-5 Hydrogen Sulfide Detector
MSA FlameGard® 5 Series Flame Detectors
Ultima OPIR-5 Open Path Infrared Gas Detector
MSA Ultima X Series Gas Detection Monitors
MSA XCell Sensor Gas Detection Technology
MSA SafEye™ 800 Open-Path Combustible Gas Detection System
MSA Permanent Gas Monitoring System Custom Products
MSA SUPREMATouch Controller
FlameGard® MSIR & UV/IR Performance Comparison and Test Lamp How-to
MSA GasGard XL Controller
Your One-Stop Service for All Your Gas Detection Needs
Speak to MSA Specialist Today